CRC Series Flow Fan-Powered Sensible Cooling VAV Terminal Units
Quiet operation, constant airflow, sensible cooling
Keep building occupants comfortable with a quiet, efficient, fan-powered VAV terminal unit with sensible cooling capability. This energy-efficient heating and cooling system delivers clean, healthy air to your commercial space—at a temperature that always feels just right.
- CFM: 100 to 1,600 CFM
- ETL =certified and labeled to meet industry safety standards
- Sensible cooling coil with 2, 3, 4, 6, and 8 row coils with 5/8" headers, 3/8" and 1/2" tube options
Product Overview
Benefits
ENVIRO-TEC VAV units maximize building air quality, comfort, and airflow with improved spacing and design flexibility.
Manage air volume efficiently with a VAV terminal unit that offers a range of configurations and heating control options.
Our VAV terminals deliver long-lasting performance through quiet, precise airflow to the occupied space.
ENVIRO-TEC VAV terminals offer genuine performance advantages through unique configurations, control options, and industry-leading sound data.
Features
- Tested in accordance with AHRI 880. Cooling coil is 410-certified and labeled. Coils are tested by ENVIRO-TEC at a minimum of 450 PSIG under-water and rated at 450 PSIG working pressure at 200° F
- ½-inch dual density micromat insulation
- 120-, 208-, 230-, and 277-volt, single-phase EC motors
- Optional scrim-reinforced foil-faced insulation meeting ASTM C1136 for mold, mildew, and humidity resistance; optional ½-inch or 1-inch elastomeric closed-cell foam or foil-faced fiberglass insulation; optional 1-inch or 2-inch throwaway or pleated filter located at induction inlet
- Electric heat options include staged or proportional with SSR and fused or non-fused door interlocking disconnect switches
- Factory-furnished 2-way and 3-way CW and HW piping packages with on/off, modulating, or proportional controls, and fixed flow or adjustable flow PICV control devices
- Solo/Sync Motor Control Technology
- 20-gauge galvanized steel casing and valve
- Forward curved, dynamically balanced, direct-drive, galvanized fan wheel
- Optional piping packages available—factory-provided and factory-mounted— in 1/2-inch 2-way and 3-way, normally closed, two-position electric motorized valves
- Hot-water (CRC-WC) or electric heating coils (CRC-EH) mounted at unit discharge (optional); access plate upstream of hydronic coil is standard
- Optional consignment DDC controls (factory-mount and wire controls provided by others) or pneumatic
- Superior FlowStar Air Measuring Probe provides for lower minimum cubic feet per minute (CFM) values, which reduces energy costs and noise while maintaining comfort in the zone
- 18 month Limited Warranty
Technical Resources
Back
Next
Related Products
- 120-, 208–230-, and 277-volt, single-phase EC motors
- Solo/sync motor control technology
- Integrated 180-degree flippable high/low-voltage control enclosure with NEC bottom-access doors and additional side-access panels.
- Solo/sync motor control technology
- Integrated sound attenuator
- Integrated 180-degree flippable high/low-voltage control enclosure with NEC bottom-access doors and additional side-access panels.
- 120-, 208–230-, and 277-volt, single-phase EC motors
- Solo/sync motor control technology
- Optional Metasys BACnet DDC (direct digital control)
- Available with PSC or EC motor options to meet a variety of fan powered application requirements.
- 120-, 208–230-, and 277-volt, single-phase EC motors
- Solo/sync motor control technology
- Superior FlowStar air-measuring probe provides for lower minimum CFM values, which reduce energy costs and noise while maintaining comfort in the zone.
- 120-, 208–230-, and 277-volt, single-phase EC motors
- Solo/sync motor control technology
- DDC controllers are factory-set to allow for quick unit installation and operation.
- Field changes are easily performed with the use of a Mobile Access Portal (MAP) Gateway Tool (sold separately).
- Available on Single-Duct, Series Flow, and Parallel Flow VAV Terminal Units.